State-of-art datacenters


DC-2 datacenter - Netriver
Our newest datacenter DC-2 is located in Lynnwood, the State of Washington. Built with APC solution, this facility allows us to use high-density servers. Network is BGP4 with NTT/Verio and Global Crossing that brings a very good speed for Asian customers.
- 500KW Diesel Generators
- APC InfraStruXure® Power Distribution
- Up to 21 Power Distribution Units
- Maximum of 150KW per PDU
- 120V & 208V Power Voltages Available
- 57,600 Watts Available Per Rack
- N+1 UPS redundancy
- 5 to 7 Megawatts of UPS Capacity
- Chilled Water Cooling System
- 120 Tons of Current Cooling Capacity, expandable to 1200 Tons
- N+1 Cooling Redundancy
- 23,000 Watts of Air Cooling Capacity Per Rack
- 30,000 Watts X2 of Chilled Water Capacity Per Rack
This datacenter is served for shared DirectAdmin hosting and VPS customers.


DC-1 datacenter - Colo4Dallas
Our DC-1 datacenter, based-on Dallas, the State of Texas, is a carrier hotel with 28.000 square feet of ground-level floor space. In this facility, we can build gigabit connections to 10 different providers: Internap, Level 3, AT&T, Time Warner Telecom, Quest, Cogent, Yipes, Looking Glass Networks, Alpheus and OnFiber. Our equipment is protected in an ideal colo environment:
- Cabinets laid out for optimum airflow - hot and cold aisles separate exhaust and intake
- Solid cabling routed neatly overhead - easier for moving equipment
- Facility stays a constant controlled 70 degrees
- Industry-leading Liebert air units for under-floor cooling and humidity control
- Pre-action dry pipe fire suppression rated for telecommunication equipment/computer rooms
- Integrated smoke/heat detector system
- PowerWare and Leibert UPS systems operate independently to provide true redundancy.
- Multiple diesel generators covering the entire facility remain on standby.
- If commercial power fails, automatic transfer switches (ATS) immediately activate generators, monitor electric feeds and transfer stabilized loads to generators.
- The UPS systems keep equipment seamlessly powered, preventing resets while generators kick in.
- Staff on-site 24/7/365 walk through the facility and checks equipment performance.
This facility is served for shared DirectAdmin, Helm hosting and dedicated server customers
For giving the best performance to customers around the world, gate2vn.net uses multiple datacenters in the US.
- For America and EU-based customers, we suggest our DC-1 datacenter in Texas state.
- For Asian Pacific customers, we suggest our DC-2 datacenter in Washington state
Each datacenter has redundant UPS systems, generator backup, closed circuit monitoring, 24-hour guards and redundant a/c systems.